Description

Material

 

Workroom interior is made of type 300 stainless steel. front panel is made of toughened glass, which cannot be caused negative effect by cleanness and sterilization. Thickness of front panel is no less than 5mm. 99.999% efficient HEPA filters, which meet the demand of temperature, humidity, corrosion proof and mechanical strength.

 

 

Filtering material is made of superfine fiberglass, which will not cause adverse impact on personnel, environment and facility.

 

Cabinets

 

Work area adopts R20 three Cside joint less fillet structure to enhance the self-cleaning function. Design of base stand is unique. Space between cabinets and floor makes cleaning easier.

 

Front Panel

 

 

 

The structure of front panel avoids danger to operator when suspended system cannot work correctly. Alarm device assure the safety of experiment in the specialized range.

 

 

Base stand and footrest: Burliness, simple design, no uncovered screw thread. Both of them can adjust the horizontality and stability of cabinets.

 

 

 

Motor

 

 

 

a. Thermal protection device assure the steady operation in the condition of 1.15 times of voltage rating.

 

 

b. Actiyator is installed behind the demountable and lockable control panel.

 

 

 

Collecting tank

 

 

 

The capacity of the collection tank is no less than 4000ml, which was used to collect the spatters of work area and there is no obvious leak and pervasions within one hour. One hour. One drain value under collecting tank and it is convenient for cleanliness.

 

 

Front panel alarm devices Automatic audible and visual alarm device will warn us when the height more than specialized range.

 

 

 

Leak proof

 

 

 

The parts of welding, gasket and sealing of the outer surface of pressure ventilation system has no bubble under the soap bubble experiment on the condition that the inner pressure of cabinets is 500Pa, up and down 10%.

 

HEPA filter

 

 

 

The filterability of every point, which measuring the filterable substance that can be scanned and detected is no more than 0.01%.

 

 

The filterability of every point, which measuring the filterable substance that can be scanned and detected is no more than 0.005%.

 

 

 

Stability

 

 

 

The core part of the work surface can stand more 23kg pressure without permanent distortion.

 

 

 

Temperature rise

 

 

 

The core temperature of work area will higher than the outer environment after 4 hours continuous work, nut the difference is less than 8.

 

 

Electrical receptacle: Vaporization for one minute, the equipments with the power mo more than 800W will work normally.

 

 

 

Parameters

 

External size(mm):1500*850*2200       

Internal size(mm):1300*600*660

Main filter: HEPA filter/ULPA(one piece)   

Filteration performance: 99.999% (0.1-0.3microns)

Exhaust filter: HEPA filter/ULPA(one piece) 

Filteration performance: 99.999% (0.1-0.3microns)

Inflow velocity: 0.65m/s                

Down flow velocity:0.37m/s

Air circulation:0                         

Exhaust air: 100%

Control system: microprocessor           

Front panel: Multi-layer doubling toughened glass

Lighting: >680lux    Noise: <65dB       

Clean level: class 10> class 100

Voltage: 220/50Hz    Power: 800W      

Collecting: >4000ml,fitted with draining valve

Vibration: the net displace is no more than 5rms ,when the frequency is from10Hz to 10kHz

Material: Type 304 stainless steel for working zone interior    

Stability: the core part can stand 23kg pressure without permanent distortion

Biosafety: Personnel safety: Hammer blow samples<10CFU/time Slit Samples<5CFU/time

Product safety: the microorganism germ falls<5CFU/time

Cross infection safety: the microorganism germ falls<2CGU/time

 

Package

 

Package Size(mm)

 

 

Exhaust Pipe Package(mm)

 

 

Net Weight

 

 

Gross Weight

 

 

1920x1640x980

1000x1070x570

412kg

522kg

Place of Origin China Currency
Payment Method L/C,T/T Minimum Order 1
Delivery Time 1 month Delivery
Packaging wodden case Supply Ability 5000 unit/year
Contact Info
  • Company Name:
  • Business Type:
    Manufacturer , Exporter
  • Member Since:
    1997
  • Contact Person:
    Robert Wang
  • Country:
    China [CN]
  • Comapny Address:
    No.51 South Gongye Road Licheng District
  • Phone Number:
    0086-531-81219803
  • Fax Number:
    0086-531-81219804
  • MSN:
  • Website:


Post buying leads free!
BusyTrade Helpline
My Recent History